Samarium Oxide

 

 

MATERIAL SAFETY DATA SHEET

 

 

I.   PRODUCT IDENTIFICATION

Manufacturer/Supplier:

ESPI Metals

1050 Benson Way, Ashland, OR 97520

Toll Free (800) 638-2581 * Fax (541) 488-8313

E-Mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

 

 

Product Name:     Samarium Oxide

Formula:              Sm2O3

CAS Number:       12060-58-1

 

 

II.   HAZARDOUS INGREDIENTS

Hazardous Components:  Samarium Oxide

Percent (%):                     0-100

OSHA/PEL:                        N/E

ACGIH/TLV:                      N/E

HMIS Ratings:

Health:                             2

Flammability:                  0

Reactivity:                       0

 

 

III.   PHYSICAL DATA

Boiling Point:                    N/E

Melting Point:                   N/E

Specific Gravity:              8.347 g/cc

Solubility in H2O:             Insoluble

Appearance and Odor:    White to yellowish powder or pieces, no odor.

 

 

IV.   FIRE AND EXPLOSION HAZARDS DATA

Flash Point:  N/A

Flammability:  Non-flammable

Autoignition Temperature:  N/A

Flammable LimitsUpper:  N/A       Lower:  N/A

Extinguishing Media:  Use suitable extinguishing media for surrounding material and type of fire.

Special Firefighting Procedures:  Firefighters must wear full face, self-contained breathing apparatus with full protective clothing to prevent contact with skin and eyes.

Unusual Fire & Explosion Hazard:  When heated to decomposition samarium oxide may emit toxic fumes.

 

 

V.   HEALTH HAZARD INFORMATION

Effects of Exposure:

To the best of our knowledge the chemical, physical and toxicological properties of samarium oxide have not been thoroughly investigated and recorded.

Samarium is considered a rare earth metal.  These metals are moderately to highly toxic.  The symptoms of toxicity of the rare earth elements include writhing, ataxia, labored respiration, walking on the toes with arched back, and sedation.  Rare earth oxides are much less toxic than the chlorides or citrates.  The rare earth elements exhibit low toxicity by ingestion exposure.  May lead to production of skin and lung granulomas.

Acute Effects:

Inhalation:  May cause irritation to the upper respiratory system and mucous membranes.

Ingestion:  Considered to have low toxicity by ingestion.

Skin:  May cause irritation.

Eyes:  May cause irritation.

Chronic Effects:

Inhalation:  May cause writhing, ataxia, labored respiration, walking on the toes with arched back, sedation, pneumoconiosis, hemoglobinemia and lung granulomas.

Ingestion:  May act as a blood anticoagulant.

Skin:  No chronic health effects recorded.

Eye:  No chronic health effects recorded.

Target Organs:  May affect the blood and lungs.

Medical Conditions Generally Aggravated by Exposure:  Pre-existing lung disorders.

CarcinogenicityNTP:  No       IARC:  No       OSHA:  No

 

EMERGENCY AND FIRST AID PROCEDURES:

INHALATION:  Remove to fresh air, keep warm and quiet, give oxygen if breathing is difficult and seek medical attention if symptoms persist. 

INGESTION:  Give 1-2 glasses of milk or water and induce vomiting, seek medical attention if symptoms persist.  Never induce vomiting or give anything by mouth to an unconscious person.

SKIN:  Remove contaminated clothing, brush material off skin, wash affected area with mild soap and water, seek medical attention if symptoms persist.

EYES:  Flush eyes with lukewarm water, including under upper and lower eyelids, for at least 15 minutes.  Seek medical attention if symptoms persist.

 

 

VI.   REACTIVITY DATA

Stability:  Stable

Conditions to Avoid:  Water/moisture

Incompatibility (Material to Avoid):  Strong acids, oxidizing agents, water/moisture, carbon dioxide.

Hazardous Decomposition Products:  None known

Hazardous Polymerization:  Will not occur

 

 

VII.   SPILL OR LEAK PROCEDURES

Steps to Be Taken in Case Material Is Released or Spilled:  Wear appropriate respiratory and protective equipment specified in section VIII.  Isolate spill are and provide ventilation.  Scoop or vacuum up spill using a HEPA filter and place in a closed container for proper disposal.  Take care not to raise dust.

Waste Disposal Method:  In accordance with Local, State and Federal Waste Disposal Regulations.

 

 

 

 

VIII.   SPECIAL PROTECTION INFORMATION

Respiratory Protection:  NIOSH approved dust respirator.

Ventilation:  Use local exhaust to maintain airborne exposure at low levels.  General exhaust is recommended.

Protective Gloves:  Rubber gloves

Eye Protection:  Safety glasses

Other Protective Clothing or Equipment:  Protective gear suitable to prevent contamination.

 

 

IX.   SPECIAL PRECAUTIONS

Precautions to Be Taken in Handling and Storage:  Store in a tightly sealed container.  Store in a cool, dry area.  Wash thoroughly after handling.

Other Precautions:  This material is hygroscopic.  Keep containers tightly sealed.  Protect from moisture.  Do not store together with oxidizing and acidic materials.

Work Practices:  Implement engineering and work practice controls to reduce and maintain concentration of exposure at low levels.  Use good housekeeping and sanitation practices.  Do not use tobacco or food in work area.  Wash thoroughly before eating and smoking.  Do not blow dust off clothing or skin with compressed air.  Maintain eyewash capable of sustained flushing, safety drench shower and facilities for washing.

TSCA Listed:         Yes

DOT Regulations:

Hazard Class:      None

 

 

The above information is believed to be correct, but does not purport to be all inclusive and shall be used only as a guide.  ESPI shall not be held liable for any damage resulting from handling or from contact with the above product.

 

Issued by:             S. Dierks

Issue Date:            February 2008

Home Page Content Under Periodic Table

ALLOYS

Click on the Alloy to go to the Online Catalog page.

 

Welcome to

ESPI was incorporated in 1950 with a mission to provide a competitive source for high purity metals, metal compounds and alloys. We are a valuable resource for virtually all major universities worldwide, global corporate R&D laboratories, thousands of domestic and international manufacturing companies and all U.S. government research laboratories. ESPI offers unique advantages often unavailable from larger organizations with no minimum order size & all business hour calls are handled by a competent sales representative. Automated answering systems and voice mail are not an option at ESPI.

Located within our fabrication facility is the melting department, forging & shaping areas, and the rod & wire, and sheet & foil departments providing the following manufacturing capabilities:

  • Casting of pure metals and alloys
  • Vacuum arc melting
  • Induction melting
  • Rod and wire drawing/extrusion
  • Sheet, foil and ribbon rolling
  • CNC milling and machining

Tel: 541-488-8311 - Email: sales@espimetals.com - or click the "Live Help/Chat Now" icon, upper right.

 

FORMS

ESPI produces and sells 68 elements and dozens of alloys in various forms for your custom needs. Click on the forms below to be directed to detailed information on manufacturing.

 

 

At We Keep Good Company


Aerospace and Defense
Northrop Grumman, Hewlett Packard, IBM, Lockheed-Martin, Hughes, Boeing, General Dynamics, Aerojet, Litton, General Electric


Medical Instruments & Technology
Cintron, Hologic/Lorad, Varian, Siemens Medical, St Jude Medical, ArthroCare, GE Medical, Harvard Medical School, City of Hope Medical Center, American Medical Systems, Cedars Sinai Medical Center


International
Atomic Energy of Canada, CNRS, European Synchrotron Radiation Facility, INRS, Alberta Research Council, National Research Council of Canada, UNAM, CISRO, CERN


Education
Stanford, UCLA, Harvard, Georgia Institute of Technology, Caltech, Johns Hopkins University, University of Arizonia, Penn State, University of Michigan, Princeton, Yale, University of Wollongong, University of Tokoyo, University of Toronto, Tulane, University of New South Wales, Max-Planck Institute, University of Freiburg


Government Research Labs
JPL, Los Alamos National Lab, Battelle Pacific NW National Lab, US Department of Energy, Argonne National Lab, Brookhaven National Lab, Naval Oceans Systems Center, US Air Force, Lawrence Berkeley National Lab, NASA


Green Energy
Origin Energy Solar, First Solar, Schott Solar, SunPower Corporation, Nanosolar, Inc.