Niobium Powder

 

 

SAFETY DATA SHEET

 

 

1   PRODUCT AND SUPPLIER IDENTIFICATION

Product Name:     Niobium Powder

Formula:              Nb

Supplier:              ESPI Metals

                            1050 Benson Way

                            Ashland, OR 97520

Telephone:          800-638-2581

Fax:                     541-488-8313

Email:                  This email address is being protected from spambots. You need JavaScript enabled to view it.

Emergency:         Infotrac 800-535-5053 (US) or 352-323-3500 (24 hour)

Recommended Uses:   Scientific Research

 

 

2   HAZARDS IDENTIFICATION 

GHS Classification (29 CFR 1910.1200): Flammable solids, category 1.

GHS Label Elements:

Signal Word: Danger

Hazard Statements: H228 Flammable solid.

Precautionary Statements: P210 Keep away from heat/sparks/open flames/hot surfaces - No smoking, P280 Wear protective gloves/protective clothing/eye protection/face protection, P370+P378 In case of fire: Use Class D dry chemical extinguishing agent for extinction.

 

 

3   COMPOSITION/INFORMATION ON INGREDIENTS

Ingredient:      Niobium

CAS#:               7440-03-1

%:                    >99

EC#:                 231-113-5

 

 

4   FIRST AID MEASURES

General Measures: Remove patient from area of exposure.

INHALATION: Remove to fresh air, keep warm and quiet, give oxygen if breathing is difficult. Seek medical attention.

INGESTION: Rinse mouth with water. Do not induce vomiting. Seek medical attention. Never induce vomiting or give anything by mouth to an unconscious person.

SKIN: Remove contaminated clothing, brush material off skin, wash affected area with soap and water. Seek medical attention if irritation develops or persists.

EYES: Flush eyes with lukewarm water, including under upper and lower eyelids, for at least 15 minutes. Seek medical attention if irritation develops or persists.

Most Important Symptoms/Effects, Acute and Delayed: May cause irritation. See section 11 for more information.

Indication of Immediate Medical Attention and Special Treatment: No other relevant information available.

 

 

5   FIREFIGHTING MEASURES

Extinguishing Media: Use Class D dry powder extinguishing agent or dry table salt.

Unsuitable Extinguishing Media: Do not use water, carbon dioxide or halocarbon extinguishing agents.

Specific Hazards Arising from the Material: Fine dust dispersed in air in sufficient concentrations, and in the presence of an ignition source, is a potential dust explosion hazard. May release niobium oxide fume if involved in a fire.

Special Protective Equipment and Precautions for Firefighters: Wear full face, self-contained breathing apparatus and full protective clothing.

 

 

6   ACCIDENTAL RELEASE MEASURES

Personal Precautions, Protective Equipment, and Emergency Procedures: Wear appropriate respiratory and protective equipment specified in section 8. Isolate spill area and provide ventilation. Avoid breathing dust or fume. Avoid contact with skin and eyes. Eliminate all sources of ignitionn.

Methods and Materials for Containment and Cleaning Up: Avoid dust formation. Use only non-sparking tools and natural bristle brushes. Scoop or vacuum up spill using a vacuum rated for combustible metal dusts equipped with a HEPA filter. Place in properly labeled closed containers.

Environmental Precautions: Do not allow to enter drains or to be released to the environment.

 

 

7   HANDLING AND STORAGE

Precautions for Safe Handling: Handle in an enclosed, controlled process. Use non-sparking tools. Protect from sources of ignition. Avoid creating dust. Provide adequate ventilation if dusts are created. Avoid breathing dust or fumes. Avoid contact with skin and eyes. Wash thoroughly before eating or smoking. See section 8 for information on personal protection equipment.

Conditions for Safe Storage: Store in a cool, dry area. Store material tightly sealed in properly labeled containers. Storage area should be free of combustibles and ignition sources. See section 10 for more information on incompatible materials.

 

 

8   EXPOSURE CONTROLS AND PERSONAL PROTECTION

Exposure Limits:     Niobium

OSHA/PEL:              No exposure limit established

ACGIH/TLV:             No exposure limit established

Engineering Controls: When working with finely divided powders, handle in a controlled, enclosed environment. Ensure adequate ventilation to maintain exposures below occupational limits. Whenever possible the use of local exhaust ventilation or other engineering controls is the preferred method of controlling exposure to airborne dust and fume to meet established occupational exposure limits. Use good housekeeping and sanitation practices. Do not allow dusts to accumulate as they may present a fire hazard. Do not use tobacco or food in work area. Wash thoroughly before eating or smoking. Do not blow dust off clothing or skin with compressed air.

Individual Protection Measures, Such as Personal Protective Equipment:

Respiratory Protection: Use suitable respirator when high concentrations are present.

Eye Protection: Safety glasses

Skin Protection: Impermeable gloves, protective work clothing as necessary.

 

 

9   PHYSICAL AND CHEMICAL PROPERTIES

Appearance:

Form:                    Powder

Color:                    Gray

Odor:                     Odorless

Odor Threshold:    Not determined

pH:                                              N/A

Melting Point:                             2468±10 oC

Boiling Point:                              5127 oC

Flash Point:                                 N/A

Evaporation Rate:                       N/A

Flammability:                              Flammable solid

Upper Flammable Limit:             No data

Lower Flammable Limit:             No data

Vapor Pressure:                          No data

Vapor Density:                             N/A

Relative Density (Specific Gravity):     8.57 g/cc @ 20 oC

Solubility in H2O:                         Insoluble

Partition Coefficient (n-octanol/water):   Not determined

Autoignition Temperature:         No data

Decomposition Temperature:     No data

Viscosity:                                     N/A

 

 

10   STABILITY AND REACTIVITY

Reactivity: No data

Chemical Stability: Stable under recommended storage conditions.

Possibility of Hazardous Reactions: Dust dispersed in air and in the presence of an ignition source may be explosive. Flammable in the form of dust when exposed to sparks or flame.

Conditions to Avoid: All sources of ignition. Dusting conditions.

Incompatible Materials: Acids, oxidizing agents, fluorine, chlorine, bromine, halocarbons, carbon tetrachloride, carbon tetrafluoride, freon.

Hazardous Decomposition Products: Niobium oxide fume.

 

 

11   TOXICOLOGICAL INFORMATION

Likely Routes of Exposure: Inhalation, skin and eyes.

Symptoms of Exposure: May cause irritation if dusts or fumes are inhaled or swallowed. Fines/dusts may irritate skin and eyes.

Toxicological Effects: No data

Acute Toxicity: No data

Carcinogenicity: NTP: Not identified as carcinogenic   IARC: Not identified as carcinogenic

To the best of our knowledge the chemical, physical and toxicological characteristics of the substance are not fully known.

 

 

12   ECOLOGICAL INFORMATION

Ecotoxicity: No data

Persistence and Degradability: No data

Bioaccumulative Potential: No data

Mobility in Soil: No data

Other Adverse Effects: Do not allow material to be released to the environment. No further relevant information available.

 

 

13   DISPOSAL CONSIDERATIONS

Waste Disposal Method:

Product: Reuse or recycle material whenever possible. Dispose of in accordance with Federal, State and Local regulations.

Packaging: Dispose of in accordance with Federal, State and Local regulations.

 

 

14   TRANSPORT INFORMATION

UN Number:                          UN3089

UN Proper Shipping Name:   Metal powder, flammable, n.o.s., (Niobium)

Transport Hazard Class:       4.1

Packing Group:                      II

Marine Pollutant:                   No

 

 

15   REGULATORY INFORMATION

TSCA Listed: All components are listed.

Regulation (EC) No 1272/2008 (CLP): Flammable solids, category 1.

Canada WHMIS Classification (CPR, SOR/88-66): Flammable solids.

HMIS Ratings: Health: 1     Flammability: 3     Physical: 0

NFPA Ratings: Health: 1     Flammability: 3     Instability: 0

Chemical Safety Assessment: A chemical safety assessment has not been carried out.

 

 

16   OTHER INFORMATION

The information contained in this document is based on the state of our knowledge at the time of publication and is believed to be correct, but does not purport to be all inclusive and shall be used only as a guide. ESPI Metals makes no representation, warranty, or guarantee of any kind with respect to the information contained in this document or any use of the product based on this information. ESPI Metals shall not be held liable for any damages resulting from handling or from contact with the above product. Users should satisfy themselves that they have all current data relevant to their particular use.

 

Prepared by:             ESPI Metals

Revised/Reviewed:   July 2015

Save

Home Page Content Under Periodic Table

ALLOYS

Click on the Alloy to go to the Online Catalog page.

 

Welcome to

ESPI was incorporated in 1950 with a mission to provide a competitive source for high purity metals, metal compounds and alloys. We are a valuable resource for virtually all major universities worldwide, global corporate R&D laboratories, thousands of domestic and international manufacturing companies and all U.S. government research laboratories. ESPI offers unique advantages often unavailable from larger organizations with no minimum order size & all business hour calls are handled by a competent sales representative. Automated answering systems and voice mail are not an option at ESPI.

Located within our fabrication facility is the melting department, forging & shaping areas, and the rod & wire, and sheet & foil departments providing the following manufacturing capabilities:

  • Casting of pure metals and alloys
  • Vacuum arc melting
  • Induction melting
  • Rod and wire drawing/extrusion
  • Sheet, foil and ribbon rolling
  • CNC milling and machining

Tel: 541-488-8311 - Email: sales@espimetals.com - or click the "Live Help/Chat Now" icon, upper right.

 

FORMS

ESPI produces and sells 68 elements and dozens of alloys in various forms for your custom needs. Click on the forms below to be directed to detailed information on manufacturing.

 

 

At We Keep Good Company


Aerospace and Defense
Northrop Grumman, Hewlett Packard, IBM, Lockheed-Martin, Hughes, Boeing, General Dynamics, Aerojet, Litton, General Electric


Medical Instruments & Technology
Cintron, Hologic/Lorad, Varian, Siemens Medical, St Jude Medical, ArthroCare, GE Medical, Harvard Medical School, City of Hope Medical Center, American Medical Systems, Cedars Sinai Medical Center


International
Atomic Energy of Canada, CNRS, European Synchrotron Radiation Facility, INRS, Alberta Research Council, National Research Council of Canada, UNAM, CISRO, CERN


Education
Stanford, UCLA, Harvard, Georgia Institute of Technology, Caltech, Johns Hopkins University, University of Arizonia, Penn State, University of Michigan, Princeton, Yale, University of Wollongong, University of Tokoyo, University of Toronto, Tulane, University of New South Wales, Max-Planck Institute, University of Freiburg


Government Research Labs
JPL, Los Alamos National Lab, Battelle Pacific NW National Lab, US Department of Energy, Argonne National Lab, Brookhaven National Lab, Naval Oceans Systems Center, US Air Force, Lawrence Berkeley National Lab, NASA


Green Energy
Origin Energy Solar, First Solar, Schott Solar, SunPower Corporation, Nanosolar, Inc.